Green Home Nanterre

Owner: Condominium ownership
Architect: Atelier Zündel Cristea
Location: Paris region (France)
Construction Date: 2016

Key technologies

Triple-glazed windows
Decentralized ventilation with 96% heat recovery
No cooling – almost no heating
Heat recovery on grey water, to produce SHW (with a water-to-water heat pump)
525 m² PV panels

Energy

Gross heated floor area:
11 500 m²
Primary energy need:
23,3 kWh/m2/y (for heating, cooling, ventilation, lighting and SHW only)
Final energy consumption:
9 kWh/m2/y
Specific heating energy consumption:
3,9 kWh/(m2a) primary energy
Specific cooling energy consumption:
0,0 kWh/(m2a)
Specific hot water energy consumption:
8,9 kWh/(m²·a) primary energy
Specific electricity consumption (excl. hot water and heating)
11,4 kWh/( m²·a) primary energy, lighting & ventilation only
Renewables:

PV installed power: 120 kWp
Solar thermal installed power: None
Biomass installed power: None
Annual RES generation: 115 MWh/y
100% coverage Primary energy needs

Energy Related Data